| Model Number | Voltage | 5hr Rate |
20hr Rate |
100hr Rate |
Watts Per Cell |
Weight (lb.) | Length (in.) | Width (in.) | Height* (in.) |
| ES33-12 | 12 | 28.9 | 34 | N/A | N/A | 24.44 | 7.76 | 5.16 | 7.09 |
| SPECIFICATIONS | |||
| Nominal Voltage (V): | 12V |
||
| Nominal Capacity: | 20hour rate ( 1.7A to 10.50V ) 34Ah 10hour rate ( 3.4A to10.50V ) 34Ah 5hour rate ( 5.78A to10.20V ) 28.9h 1C ( 34A to 9.60V ) 15.3Ah 3C ( 102A to 9.60V ) 12.24Ah |
||
| Weight: | 24.44 Lbs. (11.107 kg) |
||
| Internal Resistance (at 1KHz): | 8 mΩ | ||
| Maximum Discharge Current for 30 seconds: | 680A |
||
| Maximum Discharge Current for 5 seconds: | 1360A | ||
| Operating Temperature Range: | Charge 0°C(32°F) to 40°C (104°F) Discharge -15°C(5°F) to 50°C (122°F) Storage -15°C(5°F) to 40°C (104°F) |
||
| Charge Retention (shelf life) at 20°C (68°F): | 1 month 92% 3 month 90% 6 month 80% |
||
| Charging Methods at 25°C (77°F) Cycle use: | Charging Voltage 14.4 to 15.0V Maximum Charging Current 10.2A |
||
| Standby use: | Float Charging Voltage 13.50 to 13.80V No current limit required |
||
| Life expectancy Cycle Use: | 100% depth of discharge 250 cycles 80% depth of discharge 350 cycles 50% depth of discharge 550 cycles |
||
| Standby Use: | 3~5 years |
||
| Case Material: | ABS (94-HB & 94V-0 flame retardant case) |
||
| Terminal: | F4 |
||
|
|||