Elite
LIQUID COOLED SINGLE PHASE GENERATORS

GENERATOR SET

Model Number 4723 5212T
Rated Power LP (kW) 20 25
Rated Power NG (kW) 20 25
Voltage @ 60 Hz 120/240 120/240
Phase Single Single
Frequency 60 Hz 60 Hz
Amps LP 166.6/83.8 208.3/104.2
Amps NG 166.6/83.8 208.3/104.2
Engine/Alternator RPM 3600/3600 1800/1800
Engine 1.5 Liter
In-line
4-cylinder
In-line 4-cylinder, 2.5L engine
Fuel Natural Gas/
LP Gas
Natural Gas/
LP Gas
Engine Cooling Liquid Liquid
UL2200 Listed Yes Yes
CUL Listed Yes Yes
Main Line Circuit Breaker 100 Amp 125 Amp
Dimensions (L" x W" x H") 71in.L x 29.5in.W x 36in.H 71 x 29.5 x 36
Unit Wt. (lbs.) 776 998.0 lbs

100 amp 250 v transfer switch included
200 amp, 250v transfer switch included.
GENERATOR SET

Model Number 5219 5221
Rated Power LP (kW) 30 40
Rated Power NG (kW) 27 37
Voltage @ 60 Hz 120/240 120/240
Phase Single Single
Frequency 60 Hz 60 Hz
Amps LP 250/125 333.3/166.6
Amps NG 225/112.5 308.3/154.2
Engine/Alternator RPM 1800/1800 1800/1800
Engine 3.0 Liter
V-6
3.9 Liter
V-6
Fuel Natural Gas/
LP Gas
Natural Gas/
LP Gas
Engine Cooling Liquid Liquid
UL2200 Listed Yes Yes
CUL Listed Yes Yes
Main Line Circuit Breaker 150 Amp 175 Amp
Dimensions (L" x W" x H") 77 x 33.5 x 45 77 x 33.5 x 45
Unit Wt. (lbs.) 1431 1658
GENERATOR SET 35 kW of power when using LP
27 kW of power when using natural gas

 Using LP:
45 kW of power

Using Natural Gas
37 kW of power


Model Number 5259T 5261T
Rated Power LP (kW) 35  45
Rated Power NG (kW) 35 43
Voltage @ 60 Hz 120/240 120/240
Phase Single Single
Frequency 60 Hz 60 Hz
Amps LP 291.6/145.8 333.3/166.6
Amps NG 291.6/145.8 358.3/179.2
Engine/Alternator RPM 3600/3600 3600/3600
Engine 2.4 Liter
In-line 4 cyl.
2.4 Liter
In-line 4 cyl.
Fuel Natural Gas/
LP Gas
Natural Gas/
LP Gas
Engine Cooling Liquid Liquid
UL2200 Listed Yes Yes
CUL Listed Yes Yes
Main Line Circuit Breaker 175 Amp 200 Amp
Dimensions (L" x W" x H") 77 in. L X 29.5 in. W X 45 in. H 77 x 33.5 x 45
Ship Weight
1331 2100.0 lbs

200 Amp, 250 Volt transfer switch Included
200 Amp, 250 Volt transfer switch included

CONTROLS
Start/Stop Control Cyclic cranking: 7 seconds on, 7 seconds rest. 90 seconds overcrank protection.
Automatic Low Oil Shutdown Standard
Overspeed Shutdown Standard, 70 Hz
Overcrank Protection Standard
Automatic Voltage Regulator with Over-Voltage Protection Standard
Engine Warmup 10 seconds
Engine Cool-Down 1 minute
Safety Fuse Standard
Starter Lockout Starter cannot re-engage until 5 seconds after the engine has stopped
2 Amp Timed Trickle Battery Charger Standard
Auto Switch Utility failure/7 day exercise
Off Switch Stops unit. Power is removed. Control and charger still operate
Manual / test Start with starter control, unit stays on. If utility fails,transfer to load takes place
 The GUARDIAN Elite line of liquid-cooled generators utilizes industrial grade engines for dependable service. Sound attenuated weather protective enclosures protect generator from the elements. This makes GUARDIAN Elite a powerful yet quieter generator. Compact profiles make for an appealing installation.

Standard Features

    * Exclusive Whisper-Test™ feature operates generator at low RPM during the system's weekly exercise cycle and reduces sound output by up to 50%. This fifteen-minute cycle helps maintain top running condition.
    * Built-in timed trickle charger maintains battery at optimum performance level.
    * Automatic safety shutdowns protect engine and generator in event of low oil pressure, low oil level, low coolant level, high temperature, overspeed and/or overcrank.
    * Transfer switch options are available in 100 amp, 200 amp or 400 amp sizes
    * Industrial Liquid-cooled Engine
    * Heavy Duty Cooling Package
    * Battery Charge Alternator
    * High Energy Ignition Coil
    * R100 Digital Control Panel with LED Indicators
    * UL Listed in both the US and Canada


Switching

  The completely automatic Guardian transfer switch monitors incoming voltage from the utility line - around the clock.
  When utility power is interrupted, the automatic transfer switch immediately senses the problem and signals the generator to start.
   The automatic transfer switch then safely closes off the utility line and simultaneously opens a new power line from the generator.
   Within seconds, your Guardian generator system begins supplying electricity to the critical emergency circuits of your home or business. The transfer switch continues to monitor the utility line conditions.
   When the automatic transfer switch senses the utility line voltage has returned at a steady state, it re-transfers the electrical load back to the utility line and resumes monitoring for subsequent utility loss. The generator will continue to run for an engine cool-down period of several minutes while the entire system stands ready for the next power outage.

mefast